F. WALL MOUNTED COOLING SERIES
- AUTO RANDOM RESTART
Model Board Handset
WM 10/15/20/25 F D2.0 G8
LED Indicator Light Display
Timer Power
Sleep Dry
Self Diagnosis Table
POWER SLEEP TIMER DRY
Operation / Faulty Indication
/ Timer on
Sleep mode on
Dry mode
/ Frost prevention mode
Once every 2 sec
Room air sensor contact loose / short
Twice every 2 sec
Indoor coil sensor contact loose / short
3 time every 2 sec
Gas leak
ON / ON or OFF BLINKING
29
G. WALL MOUNTED HEATPUMP SERIES
- AUTO RANDOM RESTART
Model Board Handset
WM 10/15/20/25 FR U1.4 G8
LED Indicator Light Display
Cooling Mode Dry Mode
(Green) (Orange)
Heat / Fan Mode Sleep Mode
(Red/Green) (red)
Self Diagnosis Table
COOL DRY FAN HEAT SLEEP
Operation / Faulty Indication
/ Cooling mode
Dry mode
Fan mode
/ Heat mode
/ Auto mode in heating operation
/ Auto mode in cooling operation
Defrost operation
Compressor overload protection
Indoor coil sensor contact loose / short
Outdoor coil sensor contact loose / short
Room air sensor contact loose / short
Gas leak
ON / ON or OFF BLINKING
30