McQuay MDS300B Manual de Instalação

Consulte online ou descarregue Manual de Instalação para Aparelhos de ar condicionado "split system" McQuay MDS300B. McQuay MDS300B Unit installation Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
page 2
MULTI-DIGITAL SCROLL UNITS
MDS030A(R)~MDS60A(R)
MDS080B(R)~MDS300B(R)
Engineered for exibility and performance.
TM
TM-MDS-2006
Vista de página 0
1 2 3 4 5 6 ... 43 44

Resumo do Conteúdo

Página 1 - MULTI-DIGITAL SCROLL UNITS

page 2 MULTI-DIGITAL SCROLL UNITSMDS030A(R)~MDS60A(R)MDS080B(R)~MDS300B(R)Engineered for flexibility and performance.TMTM-MDS-2006

Página 2 - Contents

page 9 Model MCC025T MCC030T MCC040T MCC050T MCC060TCooling capacity(W) 6500 7800 10600 12400 14400Heating capacity(W) 7400 8900 11600 14500 17300Powe

Página 3 - 1 General Features

page 10 Ceiling Cassette Indoor UnitModel MCK010T MCK015T MCK018T MCK020T MCK025T MCK030T MCK040T MCK050TCooling capacity(W) 2800 3600 4500 5400 650

Página 4 - 1.4 Energy Saving

page 11 4 Outlines and Dimensions4.1 Outlines & Dimension of Outdoor UnitMDS030A(R)Unit: mm840590900460204-18x12125378318606740833024012450

Página 5 - 1.7 Space Saving

page 12 H194390816100667128H294356115430H194390816100667128H294356115430MDS040A(R)/MDS050A(R)/MDS060A(R)

Página 6 - Nomenclature

page 13 ABDeta il MD Detai l MScrew Hole 1 4×20(f or s et tin g)8- 14x20 Scre w hol e 14-1 4 x20 Scr ew hole ABDeta il MD

Página 7 - 2.6 Hot Water Heater Box

page 14 MCK010,015,018,020,025,030,040,050T Unit: mmModel A B C D E F G H I J K L

Página 8 - 3 Technical Parameter

page 15 MCM020, 030, 050T Unit: mmModel A B C

Página 9 - Notes:

page 16 5 Wiring Diagram5.1 Wiring Diagram of Indoor UnitsModel: MCC008/010/015/018/020/025/030/040/050/060T LCDM~EXV~: 15Pa: 50PaTR2TR1TransformerS

Página 10 - Ceiling Duct Indoor Unit

page 17 Model: MCK025/030/040/050TModel: MCM020/030TM~EXVM~~MCON6SW3ON21SW2SW1ONDIPBAJP7SW-PBKEY1J6J5J4J2HFLFJP6J1LINENEUTRALJP2JP1JP3JP4ONDIPLNNbluer

Página 11 - Accessories: Heating Coil

page 18 Model: MCM050TModel: MDB050/060TM~EXVM~CON65ONDIP6SW2SW1ONDIP6CON3BAJP7SW-PBKEY1J5J3MFHFJP6J1LINENEUTRALJP2JP5JP456783421ONDIPLNNredyellow/gre

Página 12 - 4 Outlines and Dimensions

page 1 ContentsGeneral Features ... 2Nomencl

Página 13 - Unit: mm

page 19 Model: MDS030AModel: MDS030ARC1-2Fan 1KMSymbolSymbolEXVPWMVFUOFFOFFPWMVKMFU220V~/50HzNL5N1112EXVONHPLP314JP1JP2OFFblack27810CompressorPTCNredb

Página 14 - Unit: mm

page 20 Model: MDS040AModel: MDS040ARC1-3Fan 1KMPWMVFUOFFOFFPWMVKMFU220V~/50HzNL5N1112Fan 2OFFHPLP31314JP1JP2OFFredred27810CompressorPTCNredbluewhiteO

Página 15 - Unit: mm

page 21 Model: MDS050AModel: MDS050ARC1-3Fan 1KMPWMVFUOFFPWMVKMFU220V~/50HzL5N1112Fan 2ONHPLP31314OFFredred27810PTCNOFFONJ2.6M~M~C2C3LPHPConnecting in

Página 16

page 22 Model: MDS050ARModel: MDS060ADescription of the components and parts:OLC1-2Digital compressorFan 1KMDB3A4WVEXVPWMVFUOLKMOL12.9AOFFOFFOFFOFF4WV

Página 17 - Model: MCK010/015/018/020T

page 23 Model: MDS060ARModel: MDS060ARC1-3Fan 1KM4WVEXVPWMVFUOFFOFFOFFKMFU220V~/50HzNL5N1112EXVFan 2OFFOFFONHPLP314JP1JP2OFFblack27810CompressorPTCNre

Página 18 - Model: MCM020/030T

page 24 Model: MDS080/100/120BRKM2OL2KMLPTHPOLT1DescriptionDescriptions of the components and parts:DB3A4WVSymbolT2OL1KM118R380V/3N~/50HzTNS3.4Overcoo

Página 19 - Model: MDB050/060T

page 25 Model: MDS150BRKM2OL2T1T2OL1KM118R380V/3N~/50HzTN3.3A14.0OL1OL4ONS3.3ONS2.3OFFS3.2ONS3.4L1T2KM5OL5192123OL4KM4262524J18HPOL415J1OL5LHP3PMWKM5S

Página 20 - indoor units communicatio

page 26 Model: MDS180BKM2OL2T1T2T3R380V/3N~/50HzSTH4L1T2T1T3373635HP15KM3KM11710PMW4WV24WV1FIX3LOW-ILLV1-V2+V2-TRV1+TH3HI-1TH6TH9TH8FU71LEXV4EXV1EXV4T

Página 21

page 27 Model: MDS200/220/240BT1T2T3R380V/3N~/50HzSOL8OL2OL1OL7TH4Before overcooling circuit temperature sensor TH9After overcooling circuit temperatu

Página 22 - Jumper settin

page 28 Model: MDS260BR (Master Unit)KM2OL2T1T2OL1KM118R380V/3N~/50HzSTNS2.2OL4S1.1OL1S3.3S2.3S3.2S3.4TH4L1T2T3KM419OL3KM3262524LPHPJ1LNHP3KM2PMWKM1KM

Página 23 - Field wirin

page 2 1 General Features1.1 Wide Range and Stepless Capacity Modulation• Wide capacity modulation range (10%-100%)• According to changing the ralio

Página 24

page 29 Model: MDS280/300BR (Master Unit)KM2OL2T1T2OL1KM118R380V/3N~/50HzTNL1T2KM5OL5192123OL4KM42624J18HPOL415J1OL5LHP3PMWKM5SV111011PMWSV242FANHFANL

Página 25 - Model: MDS080/100/120B

page 30 1,838.40741,395.5372FRONT≥45°≥300mm≥ 1000mmFRONTBACKAIR OUTLET GUIDE≥450mm≥450mm≥100mm+h4≥450mm+h3≥450mm≥450mm+h2≥450mm+h1≥450mm≥450mmh2h1h4h3

Página 26 - Model: MDS150B

page 31 Handling Outdoor UnitsPlease refer to the followings to conduct moving of units; To use 4 supporting point to move units instead of 3 points,

Página 27 - Model: MDS180BR

page 32 6.2 Installation of the Combined Outdoor Units (Suitable for Model of MDS260/280/300)Two outdoor units can be grouped as one outdoor unit, to

Página 28 - Model: MDS200/220/240BR

page 33 Balance Piping Connection• Balance piping must be installed. Balance piping shall be connected through the hole of side panel or base panel o

Página 29 - Model: MDS260BR (Master Unit)

page 34 6.3 Indoor Unit InstallationTo Choose the Position of InstallationImproper installation position will influence the cooling and heating perfor

Página 30

page 35 Duct Working InstallationAir Supply Duct Working InstallationTwo types of air supply duct working are for option: round and rectangle. Roun

Página 31 - 6 Installation

page 36 There are also the hole for fresh air and exhaust air for connection with outside in indoor unit, but as for air piping, and o

Página 32 - Outdoor Unit Installation

page 37 return airsupply airsupply airsupply airsupply air air outlet fresh air inlet¢Return Air and Supply Air DirectionDrawings for p

Página 33 - D>100mm

page 38 • To check the accessories are ready• To choose the location for installation Make sure it is easy to connect cables and pipes. Select a pl

Página 34 - Balance Piping Connection

page 3 1.4 Energy SavingThe inverter system’s capacity modulation range is from 30% to 100%, while MDS system’s capacity modulation rang

Página 35 - 6.3 Indoor Unit Installation

page 39 ceiling mountingfloor standing mountingfloor standing mounting≥300mm≥400mmPULL PULL PULL PULLceiling mounting≥1000mm≤250mm≥500mm300300166mm10m

Página 36 - Duct Working Installation

page 40 2. To fix the suspending panel with screw bolt as shown as above right figure.3. To hang the unit to the suspending panel and fix screw bolt

Página 37 - Installation of Front Panel

page 41 7 TroubleshootingIf the Followings Unit Malfunction Occurred, Please Follow the Below Simple Checking Step to Fix :Symptom Analyses Solution

Página 38 - Installation of Drainage

page 42 8 Servicing and Maintenance WarningBefore maintenance service, please shut off the power supply and stop indoor andd outdoor unitsIndoor Unit

Página 39

page 43 ©2003 McQuay International +1 (800) 432-1342 www.mcquay.comISO 9002REGISTEREDS&EWhile utmost care is taken in ensuring that

Página 40 - To Install the Indoor Unit

page 4 1.7 Space Saving • Compared to scale size central air conditioning, MDS system is high centralized, no need for special equipment roo

Página 41

page 5 M CK 030 T -A M APower supply feature: 220V~/50HzMatching outdoor units: MDS seriesDesign alteration NoDesign serial No.Cooling capacity No.Cei

Página 42 - 7 Troubleshooting

page 6 2.7 MDS UnitMDS 060 A R- F AAHeat pump, omitted if cooling only unitPower supply features: A: 220V~/50Hz F:

Página 43 - 8 Servicing and Maintenance

page 7 3 Technical ParameterMDS030A(R)~MDS060A(R)Model MDS030A MDS030AR MDS040A MDS040AR MDS050A MDS050AR MDS060A MDS060ARCooling(kW) 8.5 8.5 10.0 10

Página 44 - REGISTERED

page 8 Model MDS180B MDS180BR MDS200B MDS200BR MDS220B MDS220BR MDS240B MDS240BRCooling(kW) 47.5 47.5 50.0 50.0 55.0 55.0 65.0 65.0Heating(kW) - 50.0

Comentários a estes Manuais

Sem comentários