M5MSX-2009
Application Information
Piping Connection To The Units
• The outdoor unit is equipped with two to four sets of are joints depending on O/D unit model. Refer to table
below for are joint size and location.
• In the case where gas pipe from the indoor unit does not match the outdoor are joints, two different are
joint connectors are provided. The connector should be connected as shown in gure.
No Flarte Joint Connector
1 3/7” to 1/2” Connector
2 1/2” to 3/8” Connector
Pipe Size mm/(in) Torque Nm/(ft - Ib)
6.35 (1/4) 18 (13.3)
9.53 (3/8) 42 (31.0)
12.70 (1/2) 55 (40.6)
• Align the center of the piping and tighten the are nut sufciently with ngers.
• Finally, tighten the are nut with the torque wrench until the wrench clicks.
FLARE JOINT CONNECTOR
FLARE TUBE
INDOOR PIPING
FLARE NUT
SPANNER
TORQUE WRENCH