M5CCWS025CR/M5WSS025AR
Heating mode (Heatpump)
Water Flow Rate = 0.84 m
3
/hr
Water Flow Rate = 1.40 m
3
/hr
Water Flow Rate = 1.96 m
3
/hr
Note:
1. TC = Total Capacity, EWT = Entering Water Temperature
2. All datas above are generated at delta T = Entering Water Temperature - Leaving Water Temperature = 5
°C
140
EWT Capacity
(°C) (kW) 15 17 19 20 22 24 27 30
10
TC
6.46 6.33 6.21 6.14 6.01 5.89 5.71 5.53
12
TC
6.79 6.66 6.53 6.46 6.34 6.21 6.01 5.82
15
TC
7.28 7.15 7.01 6.95 6.82 6.68 6.47 6.26
20
TC
8.09 7.96 7.82 7.75 7.62 7.46 7.23 7.00
25
TC
8.73 8.58 8.44 8.36 8.21 8.04 7.77 7.51
30
TC
9.37 9.21 9.05 8.97 8.81 8.61 8.32 8.02
32
TC
9.63 9.46 9.30 9.21 9.05 8.84 8.54 8.23
35
TC
10.02 9.84 9.67 9.58 9.40 9.19 8.86 8.54
EWT Capacity
(°C) (kW) 15 17 19 20 22 24 27 30
10
TC
6.84 6.71 6.57 6.51 6.37 6.24 6.05 5.85
12
TC
7.19 7.05 6.91 6.85 6.71 6.57 6.37 6.16
15
TC
7.71 7.57 7.43 7.36 7.22 7.07 6.85 6.63
20
TC
8.57 8.43 8.28 8.21 8.07 7.90 7.66 7.41
25
TC
9.25 9.09 8.93 8.85 8.70 8.51 8.23 7.95
30
TC
9.93 9.76 9.59 9.50 9.33 9.12 8.81 8.50
32
TC
10.20 10.02 9.85 9.76 9.58 9.36 9.04 8.72
35
TC
10.61 10.42 10.24 10.14 9.96 9.73 9.39 9.04
EWT Capacity
(°C) (kW) 15 17 19 20 22 24 27 30
10
TC
7.13 6.99 6.85 6.78 6.64 6.50 6.30 6.10
12
TC
7.49 7.35 7.20 7.13 6.99 6.85 6.63 6.42
15
TC
8.03 7.88 7.74 7.66 7.52 7.37 7.14 6.91
20
TC
8.93 8.78 8.63 8.55 8.40 8.23 7.97 7.72
25
TC
9.63 9.47 9.31 9.22 9.06 8.87 8.58 8.28
30
TC
10.34 10.16 9.98 9.90 9.72 9.50 9.18 8.85
32
TC
10.63 10.44 10.26 10.16 9.98 9.75 9.42 9.08
35
TC
11.05 10.86 10.66 10.57 10.37 10.14 9.78 9.42
INDOOR DB (°C)
INDOOR DB (°C)
INDOOR DB (°C)
Comentários a estes Manuais