Página 1 - DC Inverter Wall Mounted

©2004 McQuay International +1 (800) 432-1342 www.mcquay.comISO 9002REGISTEREDMWMX - 2005DC Inverter Wall MountedModels: MWMX 010FR MWMX 015FR

Página 2 - Contents

8Model : MWMX 010FR / 015FR - M5LCX 010CR / 015CRRefrigeration Cycle Diagram

Página 3 - Features

9Model : MWMX 010FR / 015FRModel : M5LCX 010CR / 015CRWiring Diagrams

Página 4 - Nomenclature

10Remote Controller Operation GuideG7 Remote ControllerTransmission source• The source where the signal willbe transmitted1Temperature setting• To set

Página 5

INDICATOR LIGHTSIR signal receiverWhen all infrared remote control operating signalhas been transmitted, the signal receiver onindoor unit will make a

Página 6 - Operating Range

12Inverter Heatpump Unit LED Indicator Lights For Inverter Heatpump UnitCool / Dry Stand-by / FanTimerHeatLED DisplayThe LED in indoor and outdoor uni

Página 7 - Standard : JIS C 9612

13Blink Fault Indication Corrective Action1 Outdoor ambient sensor error Check ambient sensor wire and connection2 Outdoor coil sensor error Check coi

Página 8 - MMWX 010FR NC CURVE

Before Operating, Please Read The Following “Safety Precautions” Carefully.To prevent injury to the user or other people and properties damage, the fo

Página 9 - Outlines And Dimensions

15CautionPlease confirm the following important points when installation• Grounding is necessaryIt may cause electrical shock if grounding is not perf

Página 10 - Refrigeration Cycle Diagram

16SPECIAL PRECAUTIONS WHEN DEALING WITH REFRIGERANT R410A UNIT1) WHAT IS NEW REFRIGERANT R410A?R410A is a new HFC refrigerant which does not damage th

Página 11 - Wiring Diagrams

d) When charging R410A, ensure that only liquid is being withdrawn from the cylinder or can. This is toensure that only the original composition of R4

Página 12 - G7 Remote Controller

Note : Installation and maintenance are to be performed only by qualified personnel who are familiar with local codes and regulations, and

Página 13

18Installation DiagramIndoor UnitOutdoor UnitCAUTION : Before installing the unit, ensure that the power supply matches the power requirement of the a

Página 14

1) Selection Of Location And Space(A) Indoor UnitInstall the fan coil (indoor) unit at a location with the following requirements• Location is suitab

Página 15 - Normal Running Mode Condition

(B) Outdoor UnitAs condensing temperature rises, evaporating temperature rises and cooling capacity drops. In order to achieve maximumcooling capacity

Página 16 - Import ant

212) Drilling Holes And Mounting Installation PlateCAUTION:i) Please check the unit weight for each model. Always ensure that the wall is sufficiently

Página 17

3) Indoor Unit Preparation• The refrigerant piping can be routed to the unit in 5direction, by using the cut outs in the unit casing.(See fig. 1)• Car

Página 18 - Special Precautions For R410A

235) Water Drainage PipingThe indoor drain pipe must be downward gradient for smooth drainage. Avoid situation as shown in figurebelow.6) WiringElectr

Página 19 - Invert cylinder

7) Refrigerant PipingMaximum Pipe Length And Maximum Number Of BendsAlways choose the shortest path for refrigerant piping and follow the recommendati

Página 20 - Installation

254) After evacuation, unscrew the spindle (diagram B) for the gas to run to indoor unit.Additional ChargeThe refrigerant gas is charged in the outdoo

Página 21 - AIR FLOW DIRECTION

The unit is designed to give a long life operation with minimum maintenance required. However, it should be regularlychecked and the following items s

Página 22 - Installation Clearance

Pre Start Up Maintenance(After Extended Shutdown)– Inspect thoroughly and clean indoor and outdoor units.– Clean or replace air filters.– Clean conden

Página 23 - CAUTION:

• Energy SavingTotal energy saved can be as high as 30% compared to the conventionally controlled units.• EfficientMcQuay DC Inverter series achieve e

Página 24 - 4) Mounting Indoor Unit

28By means of pressure readings :By means of diagnosis flow chartGenerally, there are two kinds of troubles, i.e. starting failure and insufficient co

Página 25 - General Precautions

29The most common causes of air conditioner failure to “start” are :a) Voltage not within +/- 10% of rated voltage.b) Power supply interrupted.c) Con

Página 26 - 8) Vacuuming And Charging

30Model : MWMX 010FR / 015FRPPPPParararararts Listts Listts Listts Listts List1 Assy, Mounting Plate A50013032957 10 Fan Bush C/Flow Fan Black A110140

Página 27 - Additional Charge

31Model : M5LCX 010 / 015CR1 ASSY,PAN BASE SL10/15C A50014057190 ASSY. CONTROL BOXASSY,CONDENSER COIL 5SL10/15C/10CR M5LCX 010CR A50044061024M5LCX 010

Página 28

©2005 McQuay International +1 (800) 432-1342 www.mcquay.com

Página 29 - (After Extended Shutdown)

2MWMX 010 F RModel NameWM : Wall MountedSystemX : DC InverterBrandM : McQuayCapacity010 : 10,000 Btu/hSeriesF : F seriesModel TypeR : heatpumpOmitted

Página 30

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDIT

Página 31

Ensure the operating temperature is in allowable range.Cooling onlyHeatpump4 Caution :The use of your air conditioneroutside the range of working

Página 32 - Model : MWMX 010FR / 015FR

Speed Overall Noise(RPM) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz A (dBA) CriteriaH (1250)323335343123163833M (1110) 32 29 32 31 27 18 14 35 30L (

Página 33 - Model : M5LCX 010 / 015CR

Measured in anechoic room at 1m front and 0.8m below the vertical centre line of the unitMeasured in anechoic room at 1m front and 0.8m below the vert

Página 34

7Indoor UnitModel : MWMX 010FR / 015FROutdoor UnitModel : M5LCX 010CR / 015CRNote : Dimension in mmNote : Dimension in mmOutlines And Dimensions